Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Features | Termination Style | Operating Temperature | Must Operate Voltage | Must Release Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
LC1K0901G7CONTACTOR Schneider Electric |
0 |
|
![]() |
TeSys | Box | Active | Chassis Mount, DIN Rail | 120VAC | 3PST-NO (3 Form A) | 9 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | - | 96 VAC | 24 VAC |
![]() |
LC1K0901Q7CONTACTOR Schneider Electric |
0 |
|
![]() |
TeSys | Box | Active | Chassis Mount, DIN Rail | 380 ~ 400VAC | 3PST-NO (3 Form A) | 9 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | - | - | - |
![]() |
LC1K0901M73P CONTACTOR 9A AC3 4KW 1NC 220V Schneider Electric |
0 |
|
![]() |
TeSys | Box | Active | Chassis Mount, DIN Rail | 220 ~ 230VAC | 3PST-NO (3 Form A) | 9 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | - | - | - |
![]() |
LC1K09017B7CONTACTOR Schneider Electric |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 24VAC | 3PST-NO (3 Form A) | 9 A | 690VAC - Max | Auxiliary Contacts | Quick Connect - 0.110"/0.250" | - | 19.2 VAC | 4.8 VAC |
![]() |
LP1K0610BD3P CONTACTOR 6A AC3 2.2KW 24VDC Schneider Electric |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 6 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 50°C | 19.2 VDC | 2.4 VDC |
![]() |
LC1K0901D7CONTACTOR Schneider Electric |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 42VAC | 3PST-NO (3 Form A) | 9 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | - | 33.6 VAC | 8.4 VAC |
![]() |
LP1K0610MDCONTACTOR Schneider Electric |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 220VDC | 3PST-NO (3 Form A) | 6 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 50°C | 176 VDC | 22 VDC |
![]() |
LC1D32KUETESYS CONTACTOR-3P-AC3- <= 440V Schneider Electric |
0 |
|
![]() |
TeSys | Box | Active | Chassis Mount, DIN Rail | 100 ~ 250VAC/DC | 3PST-NO (3 Form A) | 32 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | - | - |
![]() |
LC1K090083E7CONTACTOR SPRING Schneider Electric |
0 |
|
![]() |
TeSys | Box | Active | Chassis Mount, DIN Rail | 48VAC | 4PST-2NO/2NC (2 Form A, 2 Form B) | 20 A | 690VAC - Max | - | Spring Terminal | - | 38.4 VAC | 9.6 VAC |
![]() |
LC1K09008U7CONTACTOR 2P+2R VIS 230 240V Schneider Electric |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 230 ~ 240VAC | 4PST-NO (4 Form A) | 20 A | 690VAC - Max | - | Screw Terminal | - | - | - |